Single Use of mouth rinse plastic cup, dental injection needle and saliva ejector
- After dental treatment for each patient, we soak used dental instruments in the sodium hypochlorite solution for 10 minutes.
- Wash with dishwashing liquid
- Soak in digital ultrasonic cleaner to enhance deep cleaning in the tiny areas.
- Dental air turbine handpieces are cleaned and lubricated in handpiece maintenance machine
Autoclavable dental instrument in autoclavable pouch.
- Autoclave/Steam Sterilization with Tuttnauer 2540MK 10-15 minutes
- Control by 3M Comply SteriGage which is the steam chemical integrator.
- Oil Free/Clean Air Delivery to Dental air turbine handpiece